Our webstore uses cookies to offer a better user experience and we recommend you to accept their use to fully enjoy your navigation.
0104110000054500
New product
Features
See description for more details about the product.
Add to cart now!
0 Item Items
This product is no longer in stock
Warning: Last items in stock!
Availability date:
• Model: XH-W2020
• Supply voltage: DC 24 V
• Output voltage: equal to input voltage
• Output current: MAX 10 A
• Maximum Power: 240 W
• Temperature control range: -50 ~ 110 ℃
• Control accuracy: 0.1 ℃
• Refresh rate: 4 times/sec
• Display size: 0.56 inch
• Size: 75 x 35 x 85 mm
• Net wight: 162 g
1. Connect the power supply in the input terminal and the load in the output terminal.
2. After powering on, the screen will display the real-time temperature. Press the SET key to set the stopping temperature, using UP/DOWN buttons. After you adjust the desired temperature, confirm it by pressing the RST key.
3. Press and hold for about 5 seconds the SET key to enter in the internal functions menu. If you want to restore to the factory settings, press and hold both UP and DOWN buttons.
Code | Description | Setting range | Default value |
P0 | Working mode | C/H | C |
P1 | Hysteresis | 0.1 - 30℃ | 2 |
P2 | MAX temperature setting range | 110℃ | 110℃ |
P3 | MIN temperature setting range | -50℃ | -50℃ |
P4 | Temperature correction | -10.0 ~ 10.0 | 0 |
P5 | Delay start time | 0 - 10 min | 0 |
P6 | High-temperature alarm | -50 ~ 110℃ | OFF |
P7 | Data lock | ON/OFF | OFF |
P8 | Reset | ON/OFF | OFF |
High temperature start for cooling mode, please set to C
Low temperature start for heating mode, please set to H
In heating mode (H): measured value ≤ set value - start output heating to set value stop when returning
In cooling mode (C), when the measured value ≥ set value + hysteresis, the output cooling is started to the set value stop.
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
When controlling the cooling of the compressor equipment, the delay time can be set as needed. When the controller outputs, the equipment will not start immediately, and it needs to start after the set delay time.
When the measured value is greater than this value, the screen is displayed -- and the sound alarm is dropped. Simultaneously disconnect the output.
Turn on the data lock to keep the current settings from being changed. At this time, the setting temperature and function are invalid. If you need to modify it, you need to turn off the data frequency function.
Long press SET to switch to P8, press SET to set to on, press RST to restore factory settings. You can also press and hold the + - button to disable the POST and restore to the factory settings
Fits most rotary tools for cutting...
$0.19
100 W LED with Color Temperature of 6000-6500 K...
$5.04
SK10 Linear Axis Holder See description for...
$1.92
This module is a high quality audio amplifier...
$4.80
Can only be bought if you have a company. See...
$4.79
Thermal Insulator for TEC12706 Peltier Modules...
$0.45
N60 DC Micro Motor (14500 RPM at 3 V) See...
$1.20
This is a 50 W Peltier element which can be...
$3.84
The PAM8610 audio amplifier is used for...
$6.00
Digital Thermometer with Thermostat and Relay,...
$4.53