Our webstore uses cookies to offer a better user experience and we recommend you to accept their use to fully enjoy your navigation.
0104110000055217
New product
Temperature controller easy to install, easy to use, ideal in every project.
Applications area:
See description for more details about the product.
Add to cart now!
22 Item Items
Warning: Last items in stock!
Availability date:
• Model: XH-W3012
• Temperature control range: -50 ~ 110oC
• Temperature measurement range: -50 ~ 110oC
• Temperature control accuracy: +/-0.1oC
• Temperature measurement accuracy: +/-0.1oC
• Measurement input: NTC 10K L = 1m waterproof probe
• Power Supply: AC 220 V
• Power consumption: 1500 W
• Output type: direct output MAX 10 A
• Weight: 52 g
• Size: 60 x 45 x 31 mm
Press and hold the SET button for about 3 seconds to enter in the internal functions menu. Select the parameter you want to set, using the UP/DOWN buttons, according to the below table. Press again the SET button and you can change now the value of the selected parameter, using UP/DOWN buttons. The settings you have made will automatically save. To set the start and the stop temperature, you just have to use the UP/DOWN buttons, when the controller is in the initial state.
Code | Description | Setting range | Default value |
P0 | Working mode | C/H | H |
P1 | Hysteresis | 0.1 - 30oC | 2oC |
P2 | Correction value |
-9.9 ~ 9.9oC |
0oC |
P3 | Delay start | 0 - 10 min | 0 min |
P0 Working mode: if the thermostat is used for heating, the parameter is set to H; if the thermostat is used for cooling, the parameter is set to C
P1 hysteresis value setting:
The difference between the temperature at which the thermostat switches off and the temperature at which it switches on again is the hysteresis. Now, you set a temperature of 72 – your thermostat will let the temperature rise in your house until it is 73 or 74 degrees, then cool it down to 71 degrees, and allow your system (and your energy bill) to relax for a bit, saving you wear and tear on your system.
P2 temperature correction: when the measured temperature deviates from the real value, it can be corrected with this function
Corrected temperature = Temperature before correction + Correction value
P3 delay start:
This function is used for compressor refrigeration. If you buy this thermostat for the fridge freezer, then this value must be set according to the pressure of the compressor. The general setting is 3-6 minutes.
Its screw terminals ensure best connection of...
$0.21
Heart Rate Sensor Module
$0.51
Temperature controller easy to install, easy to...
$12.00
This board is ideal for creative electronics...
$8.40
CY205/A 12 V 80x80x25 mm Fan See description...
$2.16
Features K-type thermocouple sensor L = 1m...
$21.60
Alligator Test Clip Cable 58 cm with USB Male...
$0.96
Are you in need of a bunch of bright and...
$0.24
This module has the advantage of being remote...
$15.12
Real-Time clock module based on the DS1307...
$2.28