• Model: XH-W2020
• Supply voltage: DC 12V
• Output voltage: equal to input voltage
• Output current: MAX 10A
• Maximum Power: 120W
• Temperature control range: -50 ~ 110 ℃
• Control accuracy: 0.1 ℃
• Refresh rate: 4 times/sec
• Display size: 0.56 inch
• Size: 75x35x85 mm
• Net wight: 162g
1. Connect the power supply in the input terminal and the load in the output terminal.
2. After powering on, the screen will display the real-time temperature. Press the SET key to set the stopping temperature, using UP/DOWN buttons. After you adjust the desired temperature, confirm it by pressing the RST key.
3. Press and hold for about 5 seconds the SET key to enter in the internal functions menu. If you want to restore to the factory settings, press and hold both UP and DOWN buttons.
Code | Description | Setting range | Default value |
P0 | Working mode | C/H | C |
P1 | Hysteresis | 0.1 - 30 o | 2 |
P2 | MAX temperature setting range | 110 oC | 110 oC |
P3 | MIN temperature setting range | -50 oC | -50 oC |
P4 | Temperature correction | -10.0 ~ 10.0 | 0 |
P5 | Delay start time | 0 - 10 min | 0 |
P6 | High temperature alarm | -50 ~ 110 oC | OFF |
P7 | Data lock | ON/OFF | OFF |
P8 | Reset | ON/OFF | OFF |
High temperature start for cooling mode, please set to C
Low temperature start for heating mode, please set to H
In heating mode (H): measured value ≤ set value - start output heating to set value stop when returning
In cooling mode (C), when the measured value ≥ set value + hysteresis, the output cooling is started to the set value stop.
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
When controlling the cooling of the compressor equipment, the delay time can be set as needed. When the controller outputs, the equipment will not start immediately, and it needs to start after the set delay time.
When the measured value is greater than this value, the screen is displayed -- and the sound alarm is dropped. Simultaneously disconnect the output
Turn on the data lock to keep the current settings from being changed. At this time, the setting temperature and function are invalid. If you need to modify it, you need to turn off the data frequency function.
Long press SET to switch to P8, press SET to set to on, press RST to restore factory settings. You can also press and hold the + - button to disable the POST and restore to the factory settings
This product is an AC DC voltage source that...
99,89 lei
This an LM2596 DC-DC module with voltage...
16,49 lei
TB6600 4A 42V Motor Driver Controller See...
39,99 lei
TPA3116D2 Class D Audio Amplifier Module (2 x...
39,99 lei
Soldering Iron 1 mm N22-1 Spare Tip See...
24,26 lei
40 x 40 x 2 mm Ceramic Heating Element (12 V, 6...
39,99 lei
This shield is an extension board for the...
23,99 lei
LTC3780 Buck-Boost synchronous Buck-Boost with...
98,32 lei
You can easily print with this PLA filament and...
69,99 lei
Ribbon cable saves space and time on circuit...
6,91 lei