• Working principle: Digital thermostat
• Item No.: XH-W2028
• Model: XH-W2028
• Power: up to 10A
• Color classification: power supply 12V power supply 24V power supply 220V
• Thermostat temperature range: -50~110 oC
• Connect the power supply and load according to the manual. Be careful not to overpressure and overload!
• ★ set mode, press and hold Set 5 seconds will display P0 and then press Set to enter the H heating mode / C cooling mode
• Set the required temperature, press the Set screen once and press the up and down keys to directly set the desired temperature.
• Rst is the confirmation button, long press this button to achieve the function of the switch
• Temperature control range: -50~110
• Fraction Resolution rate: -9.9 to 99.9 when 0.1 deg.] C Other temperature ranges . 1 deg.] C
• Temperature measurement accuracy: 0.2% FS
• Temperature control accuracy: 0.1 oC
• Refresh rate: 0.5 S
• Input power: 12V -24V -220V optional (see purchase parameters)
• Measurement input: NTC ( B3950=10K 0.5% ) 1 meter waterproof sensor
• Output type: output switch, maximum capacity 10A
• Environmental requirements: -30~60 oC humidity 20%-85%
• Machine size: 77*35*88mm
• Opening size: 70.5*29mm
Press and hold Set for 5 seconds to enter the internal parameter setting, press up and down to switch P0...P8 and press Rst to confirm the return.
Code | Code description | Setting range | Factory setting |
P0 | Cooling mode/heating mode | C/H | C |
P1 | Backlash setting | 0.1-30 | 2 |
P2 | Maximum setting range | 120 | 120 |
P3 | Minimum setting range | -55 | -55 |
P4 | Temperature correction | -10.0~+10.0 degrees | 0 |
P5 | Delayed start time | 0-10 minutes | 0 |
P6 | High-temperature alarm | -50~110 | off |
P7 | Data lock switch | On/off | off |
P8 | reset | On/off | off |
• P0 cooling and heating mode
• High temperature start for cooling mode, please set to C
• Low temperature start for heating mode, please set to H
• P1 hysteresis setting
• In heating mode ( H ): measured value ≤ set value - when the difference is returned, the output is heated to the set value to stop.
• In cooling mode ( C ): When the measured value ≥ set value + hysteresis, start output cooling to set value stop
• P2 maximum setting range: the highest value when setting the temperature does not exceed this value
• P3 minimum setting range: the lowest value when setting the temperature is not lower than this value
• P4 temperature correction
• When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
• P5 delay start time unit: minute
• When controlling the cooling of the compressor equipment, the delay time can be set as needed. When the controller outputs, the equipment will not start immediately. It needs to start after the set delay time.
• P6 high-temperature alarm
• When the measured value is greater than this value, the screen displays --- and the drip sound alarm, while forcibly disconnecting the output.
• P7 data lock function
• Turn on the data lock, you can keep the current settings from being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to turn off the data lock function.
• P8 factory reset
• Long press SET to switch to P8, press SET once to set to on, press Rst to restore factory settings
• You can also press and hold the +- button to disable the power-on self-test and restore the factory settings.
• Fourth, the instructions for use
• Please connect the power supply according to the parameters and wiring diagram, and connect the cooling or heating equipment to the output.
• Enter the internal settings as needed to select heating (enter P0 to select H ) or cool (enter P0 to select C ) mode
• Set the temperature method: press the Set screen once, press the upper and lower to set the desired temperature, press Rst to confirm the return.
• The OUT indicator of the panel: flashing indicates the cooling or heating start delay, and the steady light indicates the output.
• Digital tube: Display LLL for sensor open circuit; display HHH is out of measurement range, the thermostat will force power off; display --- for high-temperature alarm
Temperature sensor 1 / plastic shell bracket 2 / waterproof back cover baffle 1 / manual 1
This relay module with a light sensor can be...
14,99 lei
This is applicable in your projects that use...
54,99 lei
Useful adjustable low voltage power supply to...
49,99 lei
Ideal wires for making connections between...
7,73 lei
Waterproof 10k NTC Thermistor with 10 m Cable...
24,99 lei
This board is a simple carrier of Broadcom’s...
29,99 lei
20x zoom magnifying glasses with LEDs to...
39,99 lei
40 in 1 pcs wrench tool kit & screwdriver &...
85,23 lei
Complete Soldering Kit with Multimeter: It...
99,99 lei
CJMCU ACS758LCB-050B-PFF-T Current Sensor...
38,82 lei