Our webstore uses cookies to offer a better user experience and we recommend you to accept their use to fully enjoy your navigation.
0104110000054098
New product
Features
See description for more details about the product.
Add to cart now!
0 Item Items
This product is no longer in stock
Warning: Last items in stock!
Availability date:
• Fridge freezers
• Display cabinet temperatures
• Greenhouses
• Incubator
• PC chassis
• Industrial equipment
• Container ventilation
• Model: XH-W1308
• Temperature control range: -50 ~ 110 oC
• Temperature control accuracy: 0.1 oC
• Screen color: red
• Supply voltage: DC 24V
• Output: relay output up to 10A
• Measurement input: NTC 10K/ B3950 L = 1m
• Size: 100x48x28 mm
• Display size: 37x18 mm
1. Choose the working mode:
Press and hold for about 3 seconds the SET button and the screen will display P0 parameter, then press shortly SET again to modify the PO value: H is for heating mode and C is for cooling mode.
2. Set the hysteresis value:
3. Set the stop temperature
After the working mode and the hysteresis value were set, press ENT button to confirm and the screen will display the real-time temperature. Press shortly the SET button and the display will flash. You can now set the stop temperature using UP/DOWN buttons
If you want to modify another parameter, you have to enter in the internal settings by pressing and holding the SET button and with UP/DOWN buttons you can navigate between the parameters.
Code | Description | Setting range | Default value |
P0 | Working mode | H/C | C |
P1 | Hysteresis | 0.1 - 30 | 2.0 |
P2 | MAX limit | 110°C | 120 |
P3 | MIN limit | -50°C | -50 |
P4 | Temperature correction | -10.0 ~ 10.0°C | 0 |
P5 | Delay start | 0 - 10 min | 0 |
P6 | Alarm | -50 ~ 110 oC | OFF |
P7 | Data lock | ON/OFF | OFF |
P8 | Reset | ON/OFF | OFF |
High temperature start for cooling mode, please set to C
Low temperature start for heating mode, please set to H
In heating mode (H): measured value ≤ set value - start output heating to set value stop when returning
In cooling mode (C), when the measured value ≥ set value + hysteresis, the output cooling is started to the set value stop.
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
When controlling the cooling of the compressor equipment, the delay time can be set as needed. When the controller outputs, the equipment will not start immediately, and it needs to start after the set delay time.
When the measured value is greater than this value, the screen is displayed -- and the sound alarm is dropped. Simultaneously disconnect the output
Turn on the data lock to keep the current settings from being changed. At this time, the setting temperature and function are invalid. If you need to modify it, you need to turn off the data frequency function.
Long press SET to switch to P8, press SET to set to on, press ENT to restore factory settings.
You can also press and hold the + - button to disable the POST and restore the factory settings
This miniature U shape photoelectric sensor is...
4,06 lei
This development board is perfect for larger...
72,99 lei
The product is suitable for your projects if...
12,99 lei
This MQ-2 gas sensor module is used for gas...
10,99 lei
Cable with SM2.54-3p Female Connector (20 cm)...
1,69 lei
KA3845D - PWM Controller, 3845, DIP8
1,99 lei
Temperature controller easy to install, easy to...
59,99 lei
This relay module with a light sensor can be...
14,99 lei
XH-W2028 refrigerator freezer cabinet...
59,99 lei
CY206/A 12 V 60x60x25 mm Fan See description...
7,99 lei