Our webstore uses cookies to offer a better user experience and we recommend you to accept their use to fully enjoy your navigation.
0104110000055309
New product
Features:
See description for more details about the product.
Add to cart now!
0 Item Items
This product is no longer in stock
Warning: Last items in stock!
Availability date:
• Temperature control range: -30 ~ 999 °C
• Resolution: 1 °C
• Temperature measurement accuracy: 0.3% FS
• Temperature control accuracy: 0.1 °C
• Refresh rate: 2 times/sec
• Power Supply: AC 220 V
• Measurement input: K-type thermocouple
• Output type: 10 A temperature control output / 10 A high temperature alarm output
• Size: 77 x 35 x 88 mm
Connect the power supply according to the schematic. Be careful not to overload or overpressure the controller!
Press and hold for about 5 seconds the SET button to display the P0 parameter. Now, press again shortly SET button and choose the working mode for your device, using UP/DOWN buttons. C is for cooling and H is for heating.
When the controller is in its initial state, you can set the desired temperature for your room. Press shortly the SET button and use the UP/DOWN keys in order to set the value you want. Also, you have to press the RST key to confirm the settings. If you need to make another change to the controller, you have to enter in the parameters menu. Press the long SET key and choose the parameter you want to set, using the UP/DOWN buttons.
Code | Description | Setting range | Default value |
P0 | Working mode | C/H | H |
P1 | Hysteresis | 1 - 100 | 2 |
P2 | Temperature correction | -10 ~ 10 | 0 |
P3 | Alarm | -29 ~ 999 | OFF |
P4 | Data lock | ON/OFF | OFF |
High temperature start for cooling mode, please set to C
Low temperature start for heating mode, please set to H
In heating mode (H): measured value ≤ set value - start output heating to set value stop when returning
In cooling mode (C), when the measured value ≥ set value + hysteresis, the output cooling is started to the set value stop.
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
When the measured value is greater than this value, the screen is displayed -- and the sound alarm is dropped. Simultaneously disconnect the output
Turn on the data lock to keep the current settings from being changed. At this time, the setting temperature and function are invalid. If you need to modify it, you need to turn off the data frequency function.
3D printer platform special high temperature...
9,99 lei
Pot Magnet with Internal Thread 29X10XM5 See...
14,75 lei
SMA connector can be used in microwave systems...
5,99 lei
Raspberry Pi Zero - one of the most powerful...
27,03 lei
These heat sinks have profiles which are short...
3,99 lei
Pin Header 2.54 mm for Raspberry Pi Zero (40p)...
3,99 lei
The 6 V DC 4000 mA power adapter is designed to...
24,99 lei
Neodymium Block Magnet 10x10x10 Thick N48 See...
9,99 lei
HD Female to Mini HD Male Adapter See...
5,99 lei
Super speed - up to 600 MBPS data transfer rate...
14,99 lei