Our webstore uses cookies to offer a better user experience and we recommend you to accept their use to fully enjoy your navigation.
0104110000054814
New product
Technical Parameters
See description for more details about the product.
Add to cart now!
85 Item Items
Warning: Last items in stock!
Availability date:
Code | Code Description | Predetermined Area | Factory Settings | Unit |
P0 | Operating mode | C/H | C | - |
P1 | Hysteresis value | 0.1 - 30 | 2 | °C |
P2 | Temperature correction | -10.0 ~ 10.0 | 0 | °C |
P3 | Output delay | 0 - 10 | 0 | min |
P4 | High-Temperature Alarm | -50 ~ 110 | 110 | °C |
Press and hold the + button for 3 sec to restore the factory settings |
• C: cooling mode
• H: heating mode
E.g: P1 = 5
Cooling mode: when the detected temperature reaches the set value, the relay is disconnected and the temperature drops 5oC.
Heating mode: when the detected temperature reaches the set value, the relay is disconnected and the temperature rises 5oC.
This function ca be used to correct if there is a deviation between the detected temperature and the actual temperature.
AT = MT + CV ,where AT - actual value MT - measured temperature CV - correction value
If we measure the temperature to be 25.6oC and the actual is 25.8oC, CV can be set to 0.2 then the final temperature is 25.6 + 0.2 = 25.8
This function is used for compressor refrigeration. If you buy this thermostat for the fridge freezer, then this value must be set according to the pressure of compressor. The general setting is 3-6 minutes.
Set the high temperature alarm value. When the detected temperature exceeds, the screen will flash to alert you!
1. After powering the thermostat, you will se a red temperature which is the detected temperature and a green one which is controlling temperature
2. Press shortly the SET button and you will be able now to set the temperature using +/- buttons
3. Press and hold for 3 seconds the SET button and you will be able to set the thermostat parameters, according to the upper list, using the +/- buttons
4. Press shortly the SET button. Now, you can set the selected parameter.
5. Press and hold for 3 seconds the SET button or wait 5 seconds and the thermostat will be in the initial state.
Molex Female to Molex Male + Serial ATA Power...
2,06 lei
Speaker Cable Red / Black (2 x 4 mm by Meter)...
2,49 lei
You can easily print with this PLA filament and...
69,99 lei
Protection Cover Grid for 80 x 80 mm Cooler...
1,99 lei
SMD Test Clip Black See Description for more...
1,29 lei
Wireless Super Starter Kit with ESP8266...
79,99 lei
TIP42C Power PNP Transistor See description...
4,16 lei
A voltage boost that can boost the voltage with...
9,51 lei
Transistor IRF540 N-FET 100V 28A 150W 0.777...
2,99 lei
This product is used to connect a 9 volt...
1,29 lei